¡CELEBREMOS A MÉXICO A LO GRANDE! CON LIBROS Y SUPER DESCUENTOS   Ver más

Enviar a
CUAUHTÉMOC, Ciudad de México
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Study and implementation of anti-islanding techniques (en Inglés)
Formato
Libro Físico
Idioma
Inglés
N° páginas
68
Encuadernación
Tapa Blanda
Dimensiones
22.9x15.2x0.4 cm
Peso
0.11 kg.
ISBN13
9786202529143

Study and implementation of anti-islanding techniques (en Inglés)

Marcos Antônio Arantes de Freitas (Autor) · Ghunter Paulo Viajante (Autor) · Eric Nery Chaves (Autor) · LAP Lambert Academic Publishing · Tapa Blanda

Study and implementation of anti-islanding techniques (en Inglés) - Freitas, Marcos Antônio Arantes de ; Viajante, Ghunter Paulo ; Chaves, Eric Nery

Libro Nuevo Importado
Envío: 23 a 28 días háb.
$ 1,640.37$ 984.22
-40%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan 10 unidades

$ 984.22
¡Envío Gratis!  Llega entre el 07 Oct y el 15 Oct a CUAUHTÉMOC, Ciudad de México. Seleccionar ubicación

Reseña del libro "Study and implementation of anti-islanding techniques (en Inglés)"

This work presents a dynamics study of the Switched Reluctance Generator (SRG) dynamics when connected to a three-phase AC power grid. A mathematical model that includes magnetic saturation is used to represent the SRG, which is driven by an asymmetric half bridge converter. Output generated voltage is smoothed with a shunt capacitor leading to a DC link voltage. This voltage is regulated using a PI compensator that controls the magnetizing angle of the generator phases. It is shown that putting a freewheeling stage between the magnetizing and the demagnetizing states per phase, allows the best use for a better usage of the mechanical power in electromechanical conversion process. Injection of active power in the grid is performed by two PI compensators that determine the modulation indexes to each sinusoidal PWM modulators that drive the three phases of the converter. This work also proposes the implementation of an islanding detection method for distributed generation (DG) systems. This method is based on voltage and frequency parameters detection. It proved to be robust and useful to detect the islanding under different load conditions and the output of the power grid.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes