¡CELEBREMOS A MÉXICO A LO GRANDE! CON LIBROS Y SUPER DESCUENTOS   Ver más

Enviar a
CUAUHTÉMOC, Ciudad de México
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada An Experimental Investigation of the Effect of Dimples on Turbine Adiabatic Film Cooling (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
102
Encuadernación
Tapa Blanda
Dimensiones
24.6x18.9x0.5 cm
Peso
0.20 kg.
ISBN13
9781288319107
Categorías

An Experimental Investigation of the Effect of Dimples on Turbine Adiabatic Film Cooling (en Inglés)

Isaac Roland (Autor) · Biblioscholar · Tapa Blanda

An Experimental Investigation of the Effect of Dimples on Turbine Adiabatic Film Cooling (en Inglés) - Roland, Isaac

Libro Nuevo Importado
Envío: 14 a 18 días háb.
$ 1,061.02$ 477.46
-55%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan 50 unidades

$ 477.46
Llega entre el 30 Sep y el 07 Oct a CUAUHTÉMOC, Ciudad de México. Seleccionar ubicación

Reseña del libro "An Experimental Investigation of the Effect of Dimples on Turbine Adiabatic Film Cooling (en Inglés)"

This experiment explored the ability of a row of cylindrical dimples' vortex shedding to entrain the cooling film in the boundary layer for longer distances, thus enhancing cooling on a turbine leading edge model. The experiment utilized a semi-cylindrical leading edge followed by an after body with straight surfaces. A foam leading edge drilled with cooling holes allowed for a determination of adiabatic film effectiveness using an Infrared Thermography (IR) technique to measure surface temperature distributions. Two test models were utilized, one with a row of seven dimples placed upstream from the cooling-hole, while the other model had a row of seven downstream. Five blowing ratios were tested: 0.5, 0.75, 1.0, 1.25, and 1.5. It was observed that the dimples introduced disturbances in the boundary layer that encouraged vertical and lateral diffusion of the cooling film that caused reattachment of coolant jet liftoff. Dimples placed upstream of the cooling hole improved spanwise averaged adiabatic film cooling effectiveness by up to 60% for far downstream locations. Dimples placed downstream of the cooling hole enhanced up to 30% for far downstream locations.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes